Real-time transesophageal echocardiography facilitates antegrade balloon aortic valvuloplasty

Cardiovasc Diagn Ther. 2016 Apr;6(2):172-9. doi: 10.21037/cdt.2015.10.07.

Abstract

We report two cases of severe aortic stenosis (AS) where antegrade balloon aortic valvuloplasty (BAV) was performed under real-time transesophageal echocardiography (TEE) guidance. Real-time TEE can provide useful information for evaluating the aortic valve response to valvuloplasty during the procedure. It was led with the intentional wire-bias technique in order to compress the severely calcified leaflet, and consequently allowed the balloon to reach the largest possible size and achieve full expansion of the aortic annulus.

Keywords: Aortic stenosis (AS); INOUE balloon; balloon aortic valvuloplasty (BAV); ultrasonics; valvular heart disease.

Publication types

  • Case Reports