Peri-implant tissue behavior around non-titanium material: Experimental study in dogs

Ann Anat. 2016 Jul:206:104-9. doi: 10.1016/j.aanat.2016.03.005. Epub 2016 Apr 1.

Abstract

The aim of this study is to assess the effectiveness of using non-titanium abutments for better establishment of peri-implant biological width and to assess the stability of the soft tissue. Forty-eight tapered dental titanium implants with internal connection of 3.5mm in diameter and 10mm length were implanted in post extraction alveoli of 6 dogs. Twenty-four abutments made in a reinforced polyetheretherketone (PEEK) formed the test group, and 24 titanium abutments, the control group. The groups were randomized. Histological, histomorphometric, ISQ and radiological analyses were performed. Greatest differences (control group vs. test group) were found at PM-Lc (Mucosa to lingual bone contact) (2.91±0.03 vs. 3.71±0.18), and to PM Lingual-IS (2.65±0.43 vs. 3.57±0.38). Reinforced PEEK constitutes an effective alternative to conventional titanium abutments, given its high rate of biocompatibility, preservation of bone height and soft tissue stability.

Keywords: Non-titanium abutment; Peri-implant tissues; Polyetheretherketone; Postextraction sockets.

Publication types

  • Comparative Study

MeSH terms

  • Animals
  • Benzophenones
  • Biocompatible Materials / adverse effects
  • Bone-Implant Interface / pathology*
  • Dental Abutments / adverse effects*
  • Dental Implants, Single-Tooth / adverse effects
  • Dental Materials / adverse effects
  • Dogs
  • Ketones / adverse effects*
  • Male
  • Materials Testing
  • Osseointegration
  • Peri-Implantitis / etiology*
  • Peri-Implantitis / pathology
  • Polyethylene Glycols / adverse effects*
  • Polymers
  • Titanium / adverse effects
  • Tooth Socket / drug effects
  • Tooth Socket / pathology*
  • Treatment Outcome

Substances

  • Benzophenones
  • Biocompatible Materials
  • Dental Materials
  • Ketones
  • Polymers
  • polyetheretherketone
  • Polyethylene Glycols
  • Titanium