Predictive value of high-sensitivity troponin T in addition to EuroSCORE II in cardiac surgery

Interact Cardiovasc Thorac Surg. 2016 Jul;23(1):133-41. doi: 10.1093/icvts/ivw060. Epub 2016 Mar 16.

Abstract

Objectives: Plasma troponins, measured by fourth-generation assays, are associated with increased mortality and morbidity after cardiac surgery. They also offer predictive information in addition to EuroSCORE, a widely used risk model after cardiac surgery. However, preoperatively measured troponin has provided no additional information to postoperative values. Whether these facts hold true also for the high-sensitivity fifth-generation troponin assay and the better calibrated risk model, EuroSCORE II, is unknown. We hypothesized that preoperative and/or postoperative high-sensitivity troponin T (hs-TnT) would increase the predictive value of EuroSCORE II.

Methods: Consecutive coronary artery bypass grafting (CABG) and other cardiac surgical patients were prospectively enrolled in a university hospital. Plasma samples and EuroSCORE II variables were collected. The primary and secondary end-points were 180-day mortality and any major adverse event within 30 days, and 961-day mortality. The data were analysed by Kaplan-Meier survival curves, regression analyses, receiver operator characteristic curves and decision curve analysis.

Results: Mortality rates in 180 days were 3.5% (15/428) in CABG and 6.4% (14/220) in other cardiac surgical patients. Survival curves differed only in patients with not only high postoperative hs-TnT value (>500 ng/l), but also high preoperative hs-TnT value (>14 ng/l), compared with patients with both hs-TnT values low. Adding hs-TnT to EuroSCORE II improved the prediction of 180-day mortality in other cardiac surgical patients (maximum net benefit of 1.5%), but not in CABG patients. Regarding major adverse events, adding hs-TnT to EuroSCORE II improved the prediction in both CABG patients and other cardiac surgical patients (maximum net benefits of 3 and 7%).

Conclusions: Elevated postoperative hs-TnT was predictive of mortality only when combined with elevated preoperative hs-TnT. Hs-TnT measurements added information to the EuroSCORE II regarding major adverse events in all cardiac surgical patients and regarding 180-day mortality in non-CABG patients.

Keywords: Adverse events; Cardiac surgery; Coronary artery bypass grafting; EuroSCORE II; High-sensitivity troponin T; Mortality.

Publication types

  • Multicenter Study
  • Observational Study

MeSH terms

  • Aged
  • Biomarkers / blood
  • Cardiac Surgical Procedures / adverse effects*
  • Cardiovascular Diseases / blood*
  • Cardiovascular Diseases / mortality
  • Cardiovascular Diseases / surgery*
  • Female
  • Humans
  • Kaplan-Meier Estimate
  • Male
  • Middle Aged
  • Morbidity
  • Postoperative Complications / blood*
  • Postoperative Complications / etiology
  • Postoperative Complications / mortality
  • Predictive Value of Tests
  • Prognosis
  • Prospective Studies
  • ROC Curve
  • Severity of Illness Index
  • Troponin T / blood*

Substances

  • Biomarkers
  • Troponin T