Electron microscopic time-lapse visualization of surface pore filtration on particulate matter trapping process

J Microsc. 2016 Sep;263(3):250-9. doi: 10.1111/jmi.12386. Epub 2016 Feb 29.

Abstract

A scanning electron microscope (SEM) was used to dynamically visualize the particulate matter (PM) trapping process on diesel particulate filter (DPF) walls at a micro scale as 'time-lapse' images corresponding to the increase in pressure drop simultaneously measured through the DPF. This visualization and pressure drop measurement led to the conclusion that the PM trapping in surface pores was driven by PM bridging and stacking at constricted areas in porous channels. This caused a drastic increase in the pressure drop during PM accumulation at the beginning of the PM trapping process. The relationship between the porous structure of the DPF and the depth of the surface pore was investigated in terms of the porosity distribution and PM penetration depth near the wall surface with respect to depth. The pressure drop calculated with an assumed surface pore depth showed a good correspondence to the measured pressure drop.

Keywords: Particulate filter; particulate matter; porous filter; scanning electron microscope; surface pore; visualization.