[Application of rafting K-wire technique for tibial plateau fractures]

Zhongguo Gu Shang. 2015 Dec;28(12):1083-5.
[Article in Chinese]

Abstract

Objective: To summarize application of rafting K-wires technique for tibial plateau fractures.

Methods: From January 2013 to January 2015,45 patients with tibial plateau fractures were treated by locking plate with rafting K-wires, including 33 males and 12 females with an average of 44.2 years old ranging from 22 to 56 years old. According to Schatzker classification, 6 cases were type II, 8 were type Ill, 4 were type IV, 4 were type V, and 5 were type VI. Allogeneic bone graft were performed for bone defects. All patients were fixed with two to five K-wires. Part of weight loading were encouraged at 3 months after operation,and full weight-loading were done at 5 months after operation. Postoperative complications were observed,and Rasmussen clinical and radiological assessment were used to evaluate clinical results.

Results: All Patients were followed up from 10 to 23 months with average of 14 months. According to Rasmussen clinical and radiological assessment, clinical scores 23.58 ± 6.33, radiological scores were 14.00 ± 6.33; and excellent and good rates were 82.2% and 77.8% respectively. Four patients occurred severe osteoporosis and collapse of articular surface; 5 patients occurred traumatic arthritis.

Conclusion: Rafting K-wires technique with anatomized armor plate could effective fix and support platform collapse and joint bone fragments, increase support surface area and reduce postoperative reduction loss rate.

Publication types

  • English Abstract

MeSH terms

  • Adult
  • Bone Wires*
  • Female
  • Fracture Fixation, Internal / instrumentation
  • Fracture Fixation, Internal / methods*
  • Humans
  • Male
  • Middle Aged
  • Tibial Fractures / surgery*