Is internal jugular vein extensibility associated with indices of fluid responsiveness in ventilated patients?

Acta Anaesthesiol Scand. 2016 Jul;60(6):723-33. doi: 10.1111/aas.12701. Epub 2016 Feb 12.

Abstract

Background: Ultrasound of the inferior vena cava provides rapid and non-invasive assessment of fluid responsiveness. We hypothesized that the extensibility of the internal jugular vein (IJV) as well reflects intravascular volume state. We assessed IJV dimensions together with pulse pressure variation (PPV) as dynamic index for fluid responsiveness in mechanically ventilated patients.

Methods: Of 50 patients after cardiac surgery were assessed. Ultrasound of IJV dimensions as well as collection of hemodynamic data were performed in 30° and horizontal (0°) position, and the ventilator- and position-induced IJV extensibilities (E-IJV) were calculated.

Results: Mean ventilator-induced E-IJV in 30° position was 56%, and mean PPV in 30° position was 13.7%. Changing the patient's position from 30° to 0° significantly reduced ventilator-induced E-IJV as well as PPV. Pearson's correlation test revealed significant association between ventilator-induced E-IJV and fluid responsiveness deduced from PPV in 0° position (r = 0.43, P < 0.005). An E-IJV threshold >5% identified patients with significantly elevated PPV values.

Conclusion: Ultrasound of the IJV and PPV as a dynamic index for fluid responsiveness can be associated under certain defined conditions. Whether or not ultrasound of the IJV can be useful to predict patient intravascular volume state should be further studied using invasive cardiac output monitoring.

Publication types

  • Observational Study

MeSH terms

  • Adult
  • Aged
  • Aged, 80 and over
  • Blood Pressure
  • Cardiac Surgical Procedures
  • Female
  • Fluid Therapy*
  • Hemodynamics
  • Humans
  • Jugular Veins / diagnostic imaging*
  • Jugular Veins / physiopathology*
  • Male
  • Middle Aged
  • Postoperative Complications / diagnostic imaging*
  • Postoperative Complications / physiopathology
  • Respiration, Artificial*
  • Stroke Volume
  • Treatment Outcome
  • Ultrasonography*