The use of [(18)F]labelled nortropane derivative 2β-carbomethoxy-3β-(4-chlorophenyl)-8-(2-fluoroethyl)-nortropane (FECNT) as a dopamine transporter ligand for PET imaging is dependent on efficient radiosynthesis method. Herein, the automated synthesis of [(18)F]FECNT from its chlorinated precursor in commercially available SynChrom [(18)F] R&D module has been developed. The synthesis unit was readily configured for the one-step synthesis from corresponding chlorinated precursor. The radiolabeling process involved a classical [(18)F]fluoride nucleophilic substitution performed at 110 °C for 12 min and finally HPLC and SPE purification. Crude [(18)F]FECNT was obtained with a radiolabeling yield of 59 ± 12% (n = 5). The average uncorrected amount of [(18)F]FECNT in the final formulated dose was 2.0 ± 0.5 GBq (32 ± 7% overall decay-corrected yields) obtained with radiochemical purity over 99% and specific activity of 55 GBq/µmol. The total duration of the procedure was 80-90 min. An automated radiosynthesis of [(18)F]FECNT with high radiochemical purity may provide a simple and robust method of radiopharmaceutical preparation for routine clinical applications.
Keywords: [18F]FECNT; automated synthesis; dopamine transporter (DAT); modular synthesis unit.
Copyright © 2016 John Wiley & Sons, Ltd.