Microbiologically Influenced Corrosion of 2707 Hyper-Duplex Stainless Steel by Marine Pseudomonas aeruginosa Biofilm

Sci Rep. 2016 Feb 5:6:20190. doi: 10.1038/srep20190.

Abstract

Microbiologically Influenced Corrosion (MIC) is a serious problem in many industries because it causes huge economic losses. Due to its excellent resistance to chemical corrosion, 2707 hyper duplex stainless steel (2707 HDSS) has been used in the marine environment. However, its resistance to MIC was not experimentally proven. In this study, the MIC behavior of 2707 HDSS caused by the marine aerobe Pseudomonas aeruginosa was investigated. Electrochemical analyses demonstrated a positive shift in the corrosion potential and an increase in the corrosion current density in the presence of the P. aeruginosa biofilm in the 2216E medium. X-ray photoelectron spectroscopy (XPS) analysis results showed a decrease in Cr content on the coupon surface beneath the biofilm. The pit imaging analysis showed that the P. aeruginosa biofilm caused a largest pit depth of 0.69 μm in 14 days of incubation. Although this was quite small, it indicated that 2707 HDSS was not completely immune to MIC by the P. aeruginosa biofilm.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Biofilms / growth & development*
  • Chromium / chemistry
  • Corrosion
  • Dielectric Spectroscopy
  • Electrochemical Techniques
  • Microscopy, Confocal
  • Photoelectron Spectroscopy
  • Pseudomonas aeruginosa / physiology*
  • Stainless Steel / chemistry*
  • Surface Properties

Substances

  • Chromium
  • Stainless Steel