Densitometric evaluation might prevent failure of knee artroplasty for aseptic loosening. An 8-year observational controlled study

Saudi Med J. 2016 Feb;37(2):212-4. doi: 10.15537/smj.2016.2.12724.

Abstract

Objectives: To study the correlation between quantitative ultrasound (QUS) expressed as stiffness index (SI) and the risk of aseptic loosening of knee arthroplasty.

Methods: An observational retrospective controlled study was performed on 85 female patients (mean age: 73.3 years) divided into 2 groups from January 2007 to March 2015 and carried out at the Orthopedic Rehabilitation Unit, Casa di Cura Eremo, Arco, Trento, Italy. Group A included 42 patients who had undergone a revision of knee prosthesis for aseptic-loosening, and group B included 43 age-matched patients who underwent primary replacement of the knee without following aseptic loosening. Patients in both groups were evaluated for SI with Achilles - QUS system at the same side of the surgery.

Results: In group A, 20/42 patients (47.6%) had an SI T-score below -2.5. In group B, 14/43 (32.5%) patients had a SI T-score below -2.5. The difference between the 2 groups was statistically significant (p=0.015).

Conclusion: Stiffness index appears to be an important predictor of aseptic loosening of the knee prosthesis. Therefore, densitometric evaluation, including SI, may be recommended before surgical knee replacement.

Publication types

  • Observational Study

MeSH terms

  • Aged
  • Aged, 80 and over
  • Arthroplasty, Replacement, Knee*
  • Case-Control Studies
  • Densitometry / methods*
  • Female
  • Humans
  • Italy / epidemiology
  • Knee Joint / diagnostic imaging
  • Middle Aged
  • Postoperative Complications / diagnostic imaging
  • Postoperative Complications / epidemiology*
  • Prosthesis Failure*
  • Reoperation
  • Retrospective Studies
  • Risk Assessment
  • Ultrasonography