HPTLC Method for the Determination of Paracetamol, Pseudoephedrine and Loratidine in Tablets and Human Plasma

J Chromatogr Sci. 2016 Apr;54(4):647-52. doi: 10.1093/chromsci/bmv184. Epub 2016 Jan 12.

Abstract

A sensitive, accurate and selective high performance thin layer chromatography (HPTLC) method was developed and validated for the simultaneous determination of paracetamol (PAR), its toxic impurity 4-aminophenol (4-AP), pseudoephedrine HCl (PSH) and loratidine (LOR). The proposed chromatographic method has been developed using HPTLC aluminum plates precoated with silica gel 60 F254 using acetone-hexane-ammonia (4:5:0.1, by volume) as a developing system followed by densitometric measurement at 254 nm for PAR, 4-AP and LOR, while PSH was scanned at 208 nm. System suitability testing parameters were calculated to ascertain the quality performance of the developed chromatographic method. The method was validated with respect to USP guidelines regarding accuracy, precision and specificity. The method was successfully applied for the determination of PAR, PSH and LOR in ATSHI(®) tablets. The three drugs were also determined in plasma by applying the proposed method in the ranges of 0.5-6 µg/band, 1.6-12 µg/band and 0.4-2 µg/band for PAR, PSH and LOR, respectively. The results obtained by the proposed method were compared with those obtained by a reported HPLC method, and there was no significance difference between both methods regarding accuracy and precision.

MeSH terms

  • Acetaminophen / analysis*
  • Acetaminophen / blood
  • Chromatography, Thin Layer / methods*
  • Humans
  • Loratadine / analysis*
  • Loratadine / blood
  • Pseudoephedrine / analysis*
  • Pseudoephedrine / blood
  • Reproducibility of Results
  • Tablets / chemistry*

Substances

  • Tablets
  • Acetaminophen
  • Loratadine
  • Pseudoephedrine