3D spatially encoded and accelerated TE-averaged echo planar spectroscopic imaging in healthy human brain

NMR Biomed. 2016 Mar;29(3):329-39. doi: 10.1002/nbm.3469. Epub 2016 Jan 8.

Abstract

Several different pathologies, including many neurodegenerative disorders, affect the energy metabolism of the brain. Glutamate, a neurotransmitter in the brain, can be used as a biomarker to monitor these metabolic processes. One method that is capable of quantifying glutamate concentration reliably in several regions of the brain is TE-averaged (1) H spectroscopic imaging. However, this type of method requires the acquisition of multiple TE lines, resulting in long scan durations. The goal of this experiment was to use non-uniform sampling, compressed sensing reconstruction and an echo planar readout gradient to reduce the scan time by a factor of eight to acquire TE-averaged spectra in three spatial dimensions. Simulation of glutamate and glutamine showed that the 2.2-2.4 ppm spectral region contained 95% glutamate signal using the TE-averaged method. Peak integration of this spectral range and home-developed, prior-knowledge-based fitting were used for quantitation. Gray matter brain phantom measurements were acquired on a Siemens 3 T Trio scanner. Non-uniform sampling was applied retrospectively to these phantom measurements and quantitative results of glutamate with respect to creatine 3.0 (Glu/Cr) ratios showed a coefficient of variance of 16% for peak integration and 9% for peak fitting using eight-fold acceleration. In vivo scans of the human brain were acquired as well and five different brain regions were quantified using the prior-knowledge-based algorithm. Glu/Cr ratios from these regions agreed with previously reported results in the literature. The method described here, called accelerated TE-averaged echo planar spectroscopic imaging (TEA-EPSI), is a significant methodological advancement and may be a useful tool for categorizing glutamate changes in pathologies where affected brain regions are not known a priori. Copyright © 2016 John Wiley & Sons, Ltd.

Keywords: 3D spectroscopic imaging; TE-averaged; compressed sensing; glutamate quantitation; human brain; non-uniform sampling.

Publication types

  • Research Support, N.I.H., Extramural

MeSH terms

  • Adult
  • Brain / diagnostic imaging*
  • Computer Simulation
  • Creatine / metabolism
  • Echo-Planar Imaging / methods*
  • Glutamic Acid / metabolism
  • Glutamine / metabolism
  • Humans
  • Imaging, Three-Dimensional*
  • Metabolome
  • Monte Carlo Method
  • Young Adult

Substances

  • Glutamine
  • Glutamic Acid
  • Creatine