Complete factorial design experiment for 3D load cell instrumented crank validation

Annu Int Conf IEEE Eng Med Biol Soc. 2015 Aug:2015:3655-8. doi: 10.1109/EMBC.2015.7319185.

Abstract

Developing of instrumentation systems for sport medicine is a promising area, that's why this research evaluates the design of a new instrumented crank arm prototype for a race bicycle projecting an experiment for indoor - outdoor comparison. This study investigated the viability of an instrumentation 3D load cell for force measurement crank, implementing a design of experiment. A Complete factorial design experiment was developed for data validation, with an Analysis of Variance (ANOVA) throwing significant results for controlled factors with response variables rms, mean and variance. A software routine allowed to obtained system variables metrics for Symmetry and Cadence analysis, which came out from Effective force bilateral comparing and speed computation. Characterization allowed achieving calibration curves that were used for data conversion in force projection channels with a linearity error of 0.29% (perpendicular), 0.55% (parallel) and 0.10% (lateral). Interactions of factors resulted significant mainly for indoor tests in symmetry and cadence was significant in interactions generally for outdoor tests. Implemented system was able to generate Effective Force graph for 3D plot symmetry analysis, torque and power symmetry for specialist's analysis.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Adult
  • Analysis of Variance
  • Bicycling / physiology*
  • Humans
  • Male
  • Research Design*
  • Sports Medicine / instrumentation*
  • Torque
  • Young Adult