Immediate screening of lead exposure in the workplace using portable X-ray fluorescence

J Occup Environ Hyg. 2016;13(2):102-11. doi: 10.1080/15459624.2015.1091959.

Abstract

The use of a portable X-ray fluorescence spectrometer (PXRF) equipped with a miniaturised X-ray tube producing a small 8 mm diameter X-ray beam required the validation of two new sampling protocols for the immediate screening of occupational lead exposure. First, lead in dust and fumes, collected by Institute of Occupational Medicine (IOM) inhalable samplers on 25 mm diameter membrane filters, is quantified using PXRF. To account for irregular dust deposition, the filters are rotated manually by quarter turns. Multiple PXRF readings are collected from the central region and from two locations in the outer region. The inner region is distinguishable from the outer region, but the two outer region locations are indistinguishable. High correlations (R(2) > 0.99) are found between the PXRF results and historical results obtained using a reference method based on a laboratory wavelength-dispersive sequential XRF instrument (WDXRF) for lead loadings between 1-161 μg. The PXRF results from the outer regions of the filters show a bias of -13% with respect to the WDXRF. Once this bias is allowed for, 95% of all PXRF results lie within -28% and +38% of the WDXRF results. Neither instrument accounts for potential dust accumulation on the walls of the IOM sampler. Therefore, methods based on their use can only be considered semi-quantitative. Second, a protocol combining direct PXRF measurements on workplace surfaces with surface wipes is designed for immediate on-site quantification of removable surface lead residues. The quantification of such residues by this method is compared with subsequent off-site wet chemistry analysis of the surface wipes. The two methods show a good correlation (R(2) ∼ 0.88). The ratio of the amount of removable residues determined by PXRF and wipe sampling is close to one with range 0.26-3.94. It is demonstrated that PXRF can be used as an effective tool for the immediate screening of occupational lead exposure. Although this article focused on lead, PXRF can identify simultaneously a number of other metals.

Keywords: Field instrument; XRF spectroscopy; in-situ measurements; lead poisoning; metals exposure; sampling methodology.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Air Pollutants, Occupational / analysis*
  • Dust / analysis
  • Environmental Monitoring / methods
  • Filtration
  • Lead / analysis*
  • Spectrometry, X-Ray Emission / methods*
  • Workplace

Substances

  • Air Pollutants, Occupational
  • Dust
  • Lead