Purpose: Development of AV-block is a frequent complication associated with transcatheter aortic valve implantation (TAVI). To date little is known about the predictive value of the HV-interval prior to TAVI with respect to the risk of AV-block development.
Methods and results: HV-interval was determined in 25 consecutive elderly patients with severe aortic valve stenosis (AS) before and immediately after TAVI. All patients subsequently underwent TAVI and 8 of these 25 patients (32%) developed complete AV-block during the TAVI procedure requiring permanent pacemaker implantation. Six of these 8 patients (75%) had marked HV prolongation (>54 ms). Pre-procedural HV-interval was significantly prolonged in the subgroup developing complete AV-block (62.1 ms±13.0 vs 49.2 ms±12.9; P=0.029). Prolongation of the HV-interval above 54 ms was associated with a higher rate of complete AV-block (sensitivity 75.0%, specificity 77.8%, P=0.01).
Conclusions: HV-interval was prolonged in approximately one third of our elderly patients with aortic valve stenosis and associated with a high rate of complete AV-block following TAVI. HV-interval is easily obtained during TAVI screening procedures, thus facilitating identification of patients at risk for complete AV-block due to TAVI and consequently enabling bespoke risk management.
Keywords: CoreValve; HV-interval; TAVI; aortic valve disease; complete AV-block; permanent pacemaker.