Modeling Sulfides, pH and Hydrogen Sulfide Gas in the Sewers of San Francisco

Water Environ Res. 2015 Nov;87(11):1980-9. doi: 10.2175/106143015X14362865226752.

Abstract

An extensive measuring campaign targeted on sewer odor problems was undertaken in San Francisco. It was assessed whether a conceptual sewer process model could reproduce the measured concentrations of total sulfide in the wastewater and H2S gas in the sewer atmosphere, and to which degree such simulations have potential for further improving odor and sulfide management. The campaign covered measurement of wastewater sulfide by grab sampling and diurnal sampling, and H2S gas in the sewer atmosphere was logged. The tested model was based on the Wastewater Aerobic/Anaerobic Transformations in Sewers (WATS) sewer process concept, which never had been calibrated to such an extensive dataset. The study showed that the model was capable of reproducing the general levels of wastewater sulfide, wastewater pH, and sewer H2S gas. It could also reproduce the general variability of these parameters, albeit with some uncertainty. It was concluded that the model could be applied for the purpose in mind.

Publication types

  • Evaluation Study

MeSH terms

  • Drainage, Sanitary
  • Hydrogen-Ion Concentration
  • Models, Theoretical*
  • Odorants
  • San Francisco
  • Sewage / analysis*
  • Sulfides / analysis*

Substances

  • Sewage
  • Sulfides