Contrast Enhancement Patterns after Irreversible Electroporation: Experimental Study of CT Perfusion Correlated to Histopathology in Normal Porcine Liver

J Vasc Interv Radiol. 2016 Jan;27(1):104-11. doi: 10.1016/j.jvir.2015.09.005. Epub 2015 Nov 4.

Abstract

Purpose: To analyze ablated tissue zones after irreversible electroporation (IRE) of porcine liver using computed tomography (CT) perfusion imaging with histopathologic correlation.

Materials and methods: Under ultrasound and CT guidance, 10 IRE ablations were performed percutaneously in three Yorkshire pigs using a single bipolar electrode. CT perfusion imaging was performed in all pigs immediately after ablation and on day 2. Pathologic sections were prepared for correlation with histopathology (hematoxylin-eosin and terminal deoxynucleotidyl transferase dUTP nick end labeling stains, 5-mm-thick slices). The short diameter of different enhancing zones on CT was correlated with the gross specimen.

Results: CT perfusion images showed three differently enhancing zones: zone 1, inner nonenhancing zone; zone 2, middle well-defined progressive internal enhancement zone; and zone 3, outer ill-defined arterial enhancement zone with rapid washout. On histopathology, zone 1 showed a strong correlation with a pale zone, and zone 2 correlated with a red zone, together accounting for the extent of cell death. Zone 3 was outside of the ablation zone and contained inflammatory cells. Each enhancing zone had different perfusion parameters.

Conclusions: CT perfusion imaging in the acute setting effectively demonstrates histopathologic tissue zones after IRE ablation. Zone 2 is unique to IRE not seen in thermal ablation, characterized by progressive intra-zonal enhancement, and its outer boundary defines the extent of cell death.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Ablation Techniques / methods
  • Animals
  • Contrast Media*
  • Electroporation / methods*
  • Liver / diagnostic imaging*
  • Liver / surgery*
  • Male
  • Models, Animal
  • Radiographic Image Enhancement*
  • Radiography, Interventional
  • Swine
  • Tomography, X-Ray Computed*
  • Ultrasonography, Interventional

Substances

  • Contrast Media