Interpretation of Negative Molecular Test Results in Patients With Suspected or Confirmed Ebola Virus Disease: Report of Two Cases

Open Forum Infect Dis. 2015 Sep 19;2(4):ofv137. doi: 10.1093/ofid/ofv137. eCollection 2015 Dec.

Abstract

Quantitative reverse-transcription polymerase chain reaction (qRT-PCR) is the most sensitive quantitative diagnostic assay for detection of Ebola virus in multiple body fluids. Despite the strengths of this assay, we present 2 cases of Ebola virus disease (EVD) and highlight the potential for false-negative results during the early and late stages of EVD. The first case emphasizes the low negative-predictive value of qRT-PCR during incubation and the early febrile stage of EVD, and the second case emphasizes the potential for false-negative results during recovery and late neurologic complications of EVD. Careful interpretation of test results are needed to guide difficult admission and discharge decisions in suspected or confirmed EVD.

Keywords: Ebola; Liberia; PCR; West Africa; hemorrhagic fever.