Background: Since the first introduction of the Bentall technique, several modifications have been proposed to improve patient outcomes and decrease intra- and post-operative complications. We describe a simplified modification of the technique that tries to lessen the intra-operative time, improve homeostasis and miminize early and late complications. Our experience with the technique and short- and long-term patient outcomes are reported.
Methods: From August 1996 to October 2013, 110 consecutive patients underwent this modified technique. The procedure used Dacron composite graft with a mechanical valve (St. Jude Medical®) for aortic root replacement. To avoid intra-operative complications, no mobilization of coronary ostia was done. Additionally, the tubular aorta was kept minimally unchanged.
Results: Total bleeding after the operation was 450 ± 105 mL. The mean duration of intensive care unit and hospital stay were 2 ± 1 and 5 ± 2 days, respectively. Sixty-six patients (60 %) were discharged from the surgical intensive care unit on the first postoperative day, 34 patients (30.9 %) were discharged on the second day and ten patients (9.1 %) needed more time to stay in the intensive care unit due to haemodynamic or respiratory problems. At 5-years follow up, survival rate was 97 %. In the three deceased patients, causes of death were mediastinitis, sepsis and myocardial infarction. No operation-related complications such as anticoagulant-related hemorrhage, valve or graft thrombosis, or coronary pseudoaneurysm were occurred during follow-up.
Conclusions: The proposed modification of the Bentall technique seems to minimize late intra-operative blood loss, improves homeostasis, shortens the operation time and is associated with excellent long-term outcomes in patients undergoing composite graft replacement of the aortic root.