Paclitaxel-Coated Balloon in Infrapopliteal Arteries: 12-Month Results From the BIOLUX P-II Randomized Trial (BIOTRONIK'S-First in Man study of the Passeo-18 LUX drug releasing PTA Balloon Catheter vs. the uncoated Passeo-18 PTA balloon catheter in subjects requiring revascularization of infrapopliteal arteries)

JACC Cardiovasc Interv. 2015 Oct;8(12):1614-22. doi: 10.1016/j.jcin.2015.07.011.

Abstract

Objectives: The aim of BIOLUX P-II (BIOTRONIK'S-First in Man study of the Passeo-18 LUX drug releasing PTA Balloon Catheter vs. the uncoated Passeo-18 PTA balloon catheter in subjects requiring revascularization of infrapopliteal arteries) trial was to compare the safety and efficacy of a novel paclitaxel-coated drug-eluting balloon (DEB) versus an uncoated balloon (percutaneous transluminal angioplasty [PTA]) in de novo or native restenotic lesions of the infrapopliteal arteries in patients with claudication and critical limb ischemia.

Background: DEB have shown promising results in femoropopliteal lesions, but data for infrapopliteal lesions are scarce.

Methods: In this prospective, multicenter, randomized first-in-man study, 72 patients were randomized 1:1 to either a Passeo-18 Lux DEB (Biotronik AG, Buelach, Switzerland) (n = 36) or Passeo-18 PTA (n = 36). Follow-up assessments were scheduled at 1, 6, and 12 months, with angiographic assessment at 6 months. Adverse events were adjudicated by an independent clinical events committee, and angiographic parameters were assessed by an independent core laboratory.

Results: The primary safety endpoint (a composite of all-cause mortality, target extremity major amputation, target lesion thrombosis, and target vessel revascularization at 30 days) was 0% in the DEB group versus 8.3% in the PTA group (p = 0.239). The primary performance endpoint (patency loss at 6 months) was 17.1% in the DEB group versus 26.1% in the PTA group (p = 0.298), and major amputations of the target extremity occurred in 3.3% versus 5.6% of the patients at 12 months, respectively.

Conclusions: The Passeo-18 Lux DEB has been proven to be safe and effective in infrapopliteal lesions with comparable outcomes to PTA.

Keywords: below-the-knee; critical limb ischemia; drug-coated balloon; drug-eluting balloon; infrapopliteal; peripheral artery disease.

Publication types

  • Comparative Study
  • Multicenter Study
  • Randomized Controlled Trial
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Adolescent
  • Adult
  • Aged
  • Aged, 80 and over
  • Amputation, Surgical
  • Angioplasty, Balloon / adverse effects
  • Angioplasty, Balloon / instrumentation*
  • Angioplasty, Balloon / mortality
  • Cardiovascular Agents / administration & dosage*
  • Coated Materials, Biocompatible*
  • Critical Illness
  • Equipment Design
  • Female
  • Humans
  • Intermittent Claudication / diagnosis
  • Intermittent Claudication / mortality
  • Intermittent Claudication / physiopathology
  • Intermittent Claudication / therapy*
  • Ischemia / diagnosis
  • Ischemia / mortality
  • Ischemia / physiopathology
  • Ischemia / therapy*
  • Limb Salvage
  • Male
  • Middle Aged
  • Paclitaxel / administration & dosage*
  • Peripheral Arterial Disease / diagnosis
  • Peripheral Arterial Disease / mortality
  • Peripheral Arterial Disease / physiopathology
  • Peripheral Arterial Disease / therapy*
  • Popliteal Artery* / diagnostic imaging
  • Popliteal Artery* / physiopathology
  • Prospective Studies
  • Radiography
  • Recurrence
  • Time Factors
  • Treatment Outcome
  • Vascular Access Devices*
  • Vascular Patency
  • Young Adult

Substances

  • Cardiovascular Agents
  • Coated Materials, Biocompatible
  • Paclitaxel