Dynamic Arterial Elastance in Predicting Arterial Pressure Increase After Fluid Challenge During Robot-Assisted Laparoscopic Prostatectomy: A Prospective Observational Study

Medicine (Baltimore). 2015 Oct;94(41):e1794. doi: 10.1097/MD.0000000000001794.

Abstract

During robot-assisted laparoscopic prostatectomy, specific physiological conditions such as carbon dioxide insufflation and the steep Trendelenburg position can alter the cardiac workload and cerebral hemodynamics. Inadequate arterial blood pressure is associated with hypoperfusion, organ damage, and poor outcomes. Dynamic arterial elastance (Ea) has been proposed to be a useful index of fluid management in hypotensive patients. We therefore evaluated whether dynamic Ea can predict a mean arterial pressure (MAP) increase ≥ 15% after fluid challenge during pneumoperitoneum and the steep Trendelenburg position.We enrolled 39 patients receiving robot-assisted laparoscopic prostatectomy. Fluid challenge was performed with 500 mL colloids in the presence of preload-dependent conditions and arterial hypotension. Patients were classified as arterial pressure responders or arterial pressure nonresponders according to whether they showed an MAP increase ≥15% after fluid challenge. Dynamic Ea was defined as the ratio between the pulse pressure variation and stroke volume variation. Receiver operating characteristic curve analysis was performed to assess the arterial pressure responsiveness after fluid challenge during robot-assisted laparoscopic prostatectomy.Of the 39 patients, 17 were arterial pressure responders and 22 were arterial pressure nonresponders. The mean dynamic Ea before fluid challenge was significantly higher in arterial pressure responders than in arterial pressure nonresponders (0.79 vs 0.61, P < 0.001). In receiver operating characteristic curve analysis, dynamic Ea showed an area under the curve of 0.810. The optimal cut-off value of dynamic Ea for predicting an MAP increase of ≥ 15% after fluid challenge was 0.74.Dynamic Ea can predict an MAP increase ≥ 15% after fluid challenge during robot-assisted laparoscopic prostatectomy. This result suggests that evaluation of arterial pressure responsiveness using dynamic Ea helps to maintain an adequate arterial blood pressure and to improve perioperative outcomes in preload-dependent patients receiving robot-assisted laparoscopic prostatectomy under pneumoperitoneum and in the steep Trendelenburg position.

MeSH terms

  • Arterial Pressure / physiology*
  • Fluid Therapy
  • Head-Down Tilt
  • Hemodynamics / physiology
  • Humans
  • Laparoscopy*
  • Male
  • Middle Aged
  • Monitoring, Physiologic
  • Pneumoperitoneum, Artificial
  • Prostatectomy / methods*
  • Robotics*
  • Stroke Volume