Lesion stiffness measured by shear-wave elastography: Preoperative predictor of the histologic underestimation of US-guided core needle breast biopsy

Eur J Radiol. 2015 Dec;84(12):2509-14. doi: 10.1016/j.ejrad.2015.10.001. Epub 2015 Oct 9.

Abstract

Objectives: To determine whether lesion stiffness measured by shear-wave elastography (SWE) can be used to predict the histologic underestimation of ultrasound (US)-guided 14-gauge core needle biopsy (CNB) for breast masses.

Methods: This retrospective study enrolled 99 breast masses from 93 patients, including 40 high-risk lesions and 59 ductal carcinoma in situ (DCIS), which were diagnosed by US-guided 14-gauge CNB. SWE was performed for all breast masses to measure quantitative elasticity values before US-guided CNB. To identify the preoperative factors associated with histologic underestimation, patients' age, symptoms, lesion size, B-mode US findings, and quantitative SWE parameters were compared according to the histologic upgrade after surgery using the chi-square test, Fisher's exact test, or independent t-test. The independent factors for predicting histologic upgrade were evaluated using multivariate logistic regression analysis.

Results: The underestimation rate was 28.3% (28/99) in total, 25.0% (10/40) in high-risk lesions, and 30.5% (18/59) in DCIS. All elasticity values of the upgrade group were significantly higher than those of the non-upgrade group (P<0.001). On multivariate analysis, the mean (Odds ratio [OR]=1.021, P=0.001), maximum (OR=1.015, P=0.008), and minimum (OR=1.028, P=0.001) elasticity values were independently associated with histologic underestimation. The patients' age, lesion size, and final assessment category on US of the upgrade group were higher than those of the non-upgrade group (P=0.046 for age; P=0.021 for lesion size; P=0.030 for US category), but these were not independent predictors of histologic underestimation on multivariate analysis.

Conclusion: Breast lesion stiffness quantitatively measured by SWE could be helpful to predict the underestimation of malignancy in US-guided 14-gauge CNB.

Keywords: Breast; Core needle biopsy; Shear-wave elastography; Underestimation.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Adult
  • Biopsy, Large-Core Needle
  • Breast / pathology
  • Breast Neoplasms / diagnostic imaging*
  • Breast Neoplasms / pathology*
  • Elasticity Imaging Techniques / methods*
  • Female
  • Humans
  • Image-Guided Biopsy
  • Middle Aged
  • Predictive Value of Tests
  • Preoperative Care / methods*
  • Retrospective Studies
  • Ultrasonography, Interventional*
  • Ultrasonography, Mammary / methods*