Single ventricle: repair of atrioventricular valve using the bridging technique

Multimed Man Cardiothorac Surg. 2015 Sep 16:2015:mmv027. doi: 10.1093/mmcts/mmv027. Print 2015.

Abstract

Atrioventricular valve regurgitation is one of the predictors of adverse outcomes after the Fontan procedure. We describe our surgical technique of GoreTex (W. L. Gore & Associates, Inc., Flagstaff, AZ, USA) bridge to repair a common atrioventricular valve in single-ventricular circulation. The repair includes a GoreTex strip that is secured to the mid-line of both superior and inferior bridging leaflets and annulus to obtain a better coaptation of the leaflets and prevent further dilatation of the annulus. We have applied this technique for 7 consecutive patients with excellent outcomes.

Keywords: Atrioventricular septal defect; Single ventricle; Valve repair.

Publication types

  • Evaluation Study
  • Research Support, Non-U.S. Gov't
  • Video-Audio Media

MeSH terms

  • Child, Preschool
  • Follow-Up Studies
  • Fontan Procedure / instrumentation
  • Fontan Procedure / methods*
  • Heart Defects, Congenital / surgery*
  • Heart Valves / surgery*
  • Heart Ventricles / abnormalities*
  • Heart Ventricles / surgery
  • Humans
  • Infant
  • Polytetrafluoroethylene
  • Treatment Outcome

Substances

  • Polytetrafluoroethylene