Short- and mid-term results after transapical transcatheter aortic valve replacement in nonagenarians

J Cardiovasc Surg (Torino). 2017 Feb;58(1):99-104. doi: 10.23736/S0021-9509.16.09038-8. Epub 2015 Sep 8.

Abstract

Background: Recent reports have suggested that advanced age may preclude favorable outcomes in transcatheter aortic valve replacement (TAVR), particularly when performed via transapical (TA) access. However, detailed examinations of TA-TAVR in nonagenarian patients are lacking in the contemporary literature. We therefore describe our experience with 25 consecutive nonagenarians who underwent TA-TAVR and report their short- and mid-term outcomes.

Methods: We identified all patients 90 years old or greater who underwent TA-TAVR between 2009-2014 at our institution. Demographic, comorbidity and echocardiographic data were obtained for all patients as were their in-hospital, 30-day, and 1-year outcomes. Overall survival was calculated using the Kaplan-Meier method.

Results: The mean Society of Thoracic Surgeons' predicted risk of mortality was 10.2% (SD±3.4). Twenty-four nonagenarians received TA-TAVR secondary to severe aortic stenosis while 1 had a valve-in-valve procedure for a regurgitant bioprosthetic valve. There were no conversions to open surgery, no aborted procedures, and no in-hospital deaths or strokes; 44% of patients (N.=11) were discharged to home. Five patients required cardiac rehospitalization within the first 30 days and 2 experienced strokes during the first year. Overall 30-day and 1-year survival were 100% and 83%, respectively.

Conclusions: TA-TAVR can safely be performed on nonagenarians subjected to otherwise standard selection criteria. Chronology should not stand as a routine contraindication to this procedure; rather, comorbidities and functional status should define patient eligibility for TA-TAVR.

MeSH terms

  • Age Factors
  • Aged, 80 and over
  • Aortic Valve Insufficiency / diagnostic imaging
  • Aortic Valve Insufficiency / mortality
  • Aortic Valve Insufficiency / therapy*
  • Aortic Valve Stenosis / diagnostic imaging
  • Aortic Valve Stenosis / mortality
  • Aortic Valve Stenosis / therapy*
  • Aortic Valve* / diagnostic imaging
  • Cardiac Catheterization / adverse effects
  • Cardiac Catheterization / instrumentation
  • Cardiac Catheterization / methods*
  • Databases, Factual
  • Female
  • Heart Valve Prosthesis
  • Heart Valve Prosthesis Implantation / adverse effects
  • Heart Valve Prosthesis Implantation / instrumentation
  • Heart Valve Prosthesis Implantation / methods*
  • Humans
  • Kaplan-Meier Estimate
  • Male
  • New York City
  • Patient Readmission
  • Patient Selection
  • Retrospective Studies
  • Risk Assessment
  • Risk Factors
  • Stroke / etiology
  • Time Factors
  • Treatment Outcome