Evolution of multi-parametric MRI quantitative parameters following transrectal ultrasound-guided biopsy of the prostate

Prostate Cancer Prostatic Dis. 2015 Dec;18(4):343-51. doi: 10.1038/pcan.2015.33. Epub 2015 Jul 21.

Abstract

Background: To determine the evolution of prostatic multi-parametric magnetic resonance imaging (mp-MRI) signal following transrectal ultrasound (TRUS)-guided biopsy.

Methods: Local ethical permission and informed written consent was obtained from all the participants (n=14, aged 43-69, mean 64 years). Patients with a clinical suspicion of prostate cancer (PSA range 2.2-11.7, mean 6.2) and a negative (PIRAD 1-2/5) pre-biopsy mp-MRI (pre-contrast T1, T2, diffusion-weighted and dynamic-contrast-enhanced MRI) who underwent 10-core TRUS-guided biopsy were recruited for additional mp-MRI examinations performed at 1, 2 and 6 months post biopsy. We quantified mp-MRI peripheral zone (PZ) and transition zone (TZ) normalized T2 signal intensity (nT2-SI); T1 relaxation time (T10); diffusion-weighted MRI, apparent diffusion coefficient (ADC); dynamic contrast-enhanced MRI, maximum enhancement (ME); slope of enhancement (SoE) and area-under-the-contrast-enhancement-curve at 120 s (AUC120). Significant changes in mp-MRI parameters were identified by analysis of variance with Dunnett's post testing.

Results: Diffuse signal changes were observed post-biopsy throughout the PZ. No significant signal change occurred following biopsy within the TZ. Left and right PZ mean nT2-SI (left PZ: 5.73, 5.16, 4.90 and 5.12; right PZ: 5.80, 5.10, 4.84 and 5.05 at pre-biopsy, 1, 2 and 6 months post biopsy, respectively) and mean T10 (left PZ: 1.02, 0.67, 0.78, 0.85; right PZ: 1.29, 0.64, 0.78, 0.87 at pre-biopsy, 1, 2 and 6 months post biopsy, respectively) were reduced significantly (P<0.05) from pre-biopsy values for up to 6 months post biopsy. Significant changes (P<0.05) of PZ-ME and AUC120 were observed at 1 month but resolved by 2 months post biopsy. PZ ADC did not change significantly following biopsy (P=0.23-1.0). There was no significant change of any TZ mp-MRI parameter at any time point following biopsy (P=0.1-1.0).

Conclusions: Significant PZ (but not TZ) T2 signal changes persist up to 6 months post biopsy, whereas PZ and TZ ADC is not significantly altered as early as 1 month post biopsy. Caution must be exercised when interpreting T1- and T2-weighted imaging early post biopsy, whereas ADC images are more likely to maintain clinical efficacy.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Adult
  • Aged
  • Contrast Media
  • Diffusion Magnetic Resonance Imaging / methods
  • Endoscopic Ultrasound-Guided Fine Needle Aspiration / methods
  • Humans
  • Image Enhancement
  • Image Processing, Computer-Assisted
  • Magnetic Resonance Imaging* / methods
  • Male
  • Middle Aged
  • Neoplasm Grading
  • Prostatic Neoplasms / diagnosis*
  • Prostatic Neoplasms / pathology

Substances

  • Contrast Media