Outcome of a modular head-neck adapter system in revision hip arthroplasty

Arch Orthop Trauma Surg. 2015 Oct;135(10):1469-74. doi: 10.1007/s00402-015-2281-z. Epub 2015 Jul 18.

Abstract

Purpose: Revision hip arthroplasty using a modular head-neck adapter gives the possibility of keeping a well-fixed femoral component while revising the acetabular prosthesis or femoral head and adapt leg length and femoral offset to the individual anatomy intraoperatively. The success of this kind of surgery is still unclear due to the lack of medium- to long-term follow-up. Therefore, we analyzed the clinical and radiological outcome of the modular Merete BioBall© adapter system in revision hip surgery.

Methods: In this retrospective study, we included 95 consecutive patients with a Merete BioBall© adapter system implanted during revision hip arthroplasty. The average follow-up was 52.5 months. For clinical evaluation, we used the Harris Hip Score. The health-related quality of life was determined with the visual analog pain scale.

Results: The surgeries were performed 97 months after prior hip arthroplasty on average. The main indications for the Merete BioBall© adapter system were dislocation, acetabular loosening, and wear. In the clinical outcome, patients achieved 80.9 points in the Harris Hip Score. The mean level of persisting pain was 1.4 (VAS). The overall survival of the Merete BioBall© system in revision hip arthroplasty revealed 92.8 % survival at 8.17 years follow-up with a repeat revision rate of 5.2 %.

Conclusions: Performing revision hip arthroplasty using the Merete BioBall

Keywords: Head–neck adapter; Hip revision arthroplasty; Merete BioBall; Modular; Outcome.