How to perform and interpret cine MR enterography

J Magn Reson Imaging. 2015 Nov;42(5):1180-9. doi: 10.1002/jmri.24981. Epub 2015 Jul 14.

Abstract

Magnetic resonance (MR) enterography has become a fundamental tool for small bowel evaluation. Multiphasic cine imaging is a useful component of MR enterography evaluation because it provides functional information about bowel motility. Cine MR enterography can be used to evaluate for strictures and adhesions. Bowel motility evaluation has been shown to increase pathologic lesion detection in Crohn's disease and has been incorporated into disease activity scoring systems. Currently, cine MR enterography remains underutilized. The purpose of this article is to outline how to perform and interpret cine MR enterography. The authors describe how to perform a multiphasic balanced steady state free precession sequence using different MR systems and give practical advice on how to display and interpret the cine sequence. Sample cases illustrate how the cine sequence complements standard MR enterography evaluation with T2 -weighted, contrast-enhanced T1 -weighted, and diffusion-weighted imaging.

Keywords: cine MR enterography; motility; peristalsis; small bowel.

Publication types

  • Review

MeSH terms

  • Crohn Disease / pathology*
  • Humans
  • Image Processing, Computer-Assisted / methods*
  • Intestine, Small / pathology*
  • Magnetic Resonance Imaging, Cine / methods*