Ultra fast-track extubation in heart transplant surgery patients

Int J Crit Illn Inj Sci. 2015 Apr-Jun;5(2):89-92. doi: 10.4103/2229-5151.158394.

Abstract

Background: Heart transplant surgeries using cardiopulmonary bypass (CPB) typically requires mechanical ventilation in intensive care units (ICU) in post-operation period. Ultra fast-track extubation (UFE) have been described in patients undergoing various cardiac surgeries.

Aim: To determine the possibility of ultra-fast-track extubation instead of late extubation in post heart transplant patients.

Materials and methods: Patients randomly assigned into two groups; Ultra fast-track extubation (UFE) group was defined by extubation inside operating room right after surgery. Late extubation group was defined by patients who were not extubated in operating room and transferred to post operation cardiac care unit (CCU) to extubate.

Results: The mean cardiopulmonary bypass time was 136.8 ± 25.7 minutes in ultra-fast extubation and 145.3 ± 29.8 minutes in late extubation patients (P > 0.05). Mechanical ventilation duration (days) was 0 days in ultra-fast and 2.31 ± 1.8 days in late extubation. Length of ICU stay was significantly higher in late extubation group (4.2 ± 1.2 days) than the UFE group (1.72 ± 1.5 days) (P = 0.02). In survival analysis there was no significant difference between ultra-fast and late extubation groups (Log-rank test, P = 0.9).

Conclusions: Patients undergoing cardiac transplant could be managed with "ultra-fast-track extubation", without increased morbidity and mortality.

Keywords: Critical care; heart transplant; heart transplant surgery; ultra fast-track extubation.