Abstract

In biology, hemocytometers such as Malassez slides are widely used and are effective tools for counting cells manually. In a previous work, a robust algorithm was developed for grid extraction in Malassez slide images. This algorithm was evaluated on a set of 135 images and grids were accurately detected in most cases, but there remained failures for the most difficult images. In this work, we present an optimization of this algorithm that allows for 100% grid detection and a 25% improvement in grid positioning accuracy. These improvements make the algorithm fully reliable for grid detection. This optimization also allows complete erasing of the grid without altering the cells, which eases their segmentation.

Keywords: Fourier transform; Malassez; homomorphic filtering; image analysis; noise filtering.

MeSH terms

  • Image Processing, Computer-Assisted / methods*
  • Microbiological Techniques / methods*
  • Microscopy / methods*