Comparison of I-123 MIBG planar imaging and SPECT for the detection of decreased heart uptake in Parkinson disease

J Neural Transm (Vienna). 2015 Oct;122(10):1421-7. doi: 10.1007/s00702-015-1409-1. Epub 2015 May 24.

Abstract

Decreased myocardial uptake of I-123 metaiodobenzylguanidine (MIBG) is an important finding for diagnosis of Parkinson's disease (PD). This study compared I-123 MIBG SPECT and planar imaging with regard to their diagnostic yield for PD. 52 clinically diagnosed PD patients who also had decreased striatal uptake on FP-CIT PET/CT were enrolled. 16 normal controls were also included. All underwent cardiac MIBG planar scintigraphy and SPECT separately. Myocardial I-123 MIBG uptake was interpreted on planar and SPECT/CT images separately by visual and quantitative analysis. The final diagnosis was made by consensus between two readers. Kappa analyses were performed to determine inter-observer agreement for both methods. Sensitivity, specificity, and accuracy were compared with McNemar's test. The sensitivity, specificity, and accuracy were 84.6, 100, and 88.2% for planar images and 96.2, 100 and 97.1% for SPECT, respectively, with a significant difference between the two imaging methods (p < 0.031). All inter-observer agreements were almost perfect (planar scintigraphy: κ = 0.82; SPECT: κ = 0.93). Heart-to-mediastinum ratios from PD patients with negative planar and positive SPECT scans (group A) and patients with positive planar and positive SPECT scans (group B) were 1.69 ± 0.16 (1.59-1.85) and 1.41 ± 0.15 (1.20-1.53), respectively, and showed significant difference (p = 0.023). Lung-to-mediastinum ratios for groups A and B were 2.16 ± 0.20 (1.96-2.37) and 1.6 ± 0.19 (1.3-1.78), respectively, and were significantly higher in the former (p = 0.001). I-123 MIBG SPECT has a significantly higher diagnostic performance for PD than planar images. Increased lung uptake may cause false-negative results on planar imaging.

Keywords: I-123 MIBG; Parkinson's disease; Planar scintigraphy; SPECT; Sensitivity and specificity.

Publication types

  • Comparative Study

MeSH terms

  • 3-Iodobenzylguanidine*
  • Aged
  • Aged, 80 and over
  • Female
  • Heart / diagnostic imaging*
  • Humans
  • Male
  • Middle Aged
  • Parkinson Disease / diagnosis
  • Parkinson Disease / diagnostic imaging*
  • Prospective Studies
  • Radiopharmaceuticals*
  • Sensitivity and Specificity
  • Tomography, Emission-Computed, Single-Photon*
  • Tropanes*

Substances

  • Radiopharmaceuticals
  • Tropanes
  • 2-carbomethoxy-8-(3-fluoropropyl)-3-(4-iodophenyl)tropane
  • 3-Iodobenzylguanidine