Novel penalised likelihood reconstruction of PET in the assessment of histologically verified small pulmonary nodules

Eur Radiol. 2016 Feb;26(2):576-84. doi: 10.1007/s00330-015-3832-y. Epub 2015 May 20.

Abstract

Objectives: Investigate the effect of a novel Bayesian penalised likelihood (BPL) reconstruction algorithm on analysis of pulmonary nodules examined with 18F-FDG PET/CT, and to determine its effect on small, sub-10-mm nodules.

Methods: 18F-FDG PET/CTs performed for nodule evaluation in 104 patients (121 nodules) were retrospectively reconstructed using the new algorithm, and compared to time-of-flight ordered subset expectation maximisation (OSEM) reconstruction. Nodule and background parameters were analysed semi-quantitatively and visually.

Results: BPL compared to OSEM resulted in statistically significant increases in nodule SUVmax (mean 5.3 to 8.1, p < 0.00001), signal-to-background (mean 3.6 to 5.3, p < 0.00001) and signal-to-noise (mean 24 to 41, p < 0.00001). Mean percentage increase in SUVmax (%ΔSUVmax) was significantly higher in nodules ≤10 mm (n = 31, mean 73%) compared to >10 mm (n = 90, mean 42 %) (p = 0.025). Increase in signal-to-noise was higher in nodules ≤10 mm (224%, mean 12 to 27) compared to >10 mm (165%, mean 28 to 46). When applying optimum SUVmax thresholds for detecting malignancy, the sensitivity and accuracy increased using BPL, with the greatest improvements in nodules ≤10 mm.

Conclusion: BPL results in a significant increase in signal-to-background and signal-to-noise compared to OSEM. When semi-quantitative analyses to diagnose malignancy are applied, higher SUVmax thresholds may be warranted owing to the SUVmax increase compared to OSEM.

Key points: • Novel Bayesian penalised likelihood PET reconstruction was applied for lung nodule evaluation. • This was compared to current standard of care OSEM reconstruction. • The novel reconstruction generated significant increases in lung nodule signal-to-background and signal-to-noise. • These increases were highest in small, sub-10-mm pulmonary nodules. • Higher SUV max thresholds may be warranted when using semi-quantitative analyses to diagnose malignancy.

Keywords: Image quality enhancement; Image reconstruction; Positron-emission tomography; Signal-to-noise ratio; Solitary pulmonary nodule.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Adult
  • Aged
  • Aged, 80 and over
  • Algorithms
  • Bayes Theorem
  • Female
  • Fluorodeoxyglucose F18
  • Humans
  • Image Processing, Computer-Assisted / methods*
  • Lung / diagnostic imaging
  • Lung Neoplasms / diagnostic imaging*
  • Male
  • Middle Aged
  • Multimodal Imaging
  • Positron-Emission Tomography / methods*
  • Radiopharmaceuticals
  • Retrospective Studies
  • Solitary Pulmonary Nodule / diagnostic imaging*
  • Tomography, X-Ray Computed
  • Young Adult

Substances

  • Radiopharmaceuticals
  • Fluorodeoxyglucose F18