Seventy-Peak Kilovoltage High-Pitch Thoracic Aortic CT Angiography without ECG Gating: Evaluation of Image Quality and Radiation Dose

Acad Radiol. 2015 Jul;22(7):890-7. doi: 10.1016/j.acra.2015.03.007. Epub 2015 Apr 11.

Abstract

Rationale and objectives: To assess the feasibility of 70-kVp high-pitch non-ECG-gated thoracic aortic computed tomography angiography (CTA) with 40-mL contrast agent compared to 100-kVp standard-pitch CTA with 60-mL contrast agent.

Materials and methods: Sixty-seven patients (51 men and 16 women; mean age, 55 ± 14 years) received non-ECG-gated aortic CTA at 70 kVp, high pitch of 3.4, and 40-mL contrast agent (group A, n = 31) or CTA at 100-kVp, pitch of 1.2, and 60-mL contrast agent (group B, n = 36). Iterative reconstruction was used in all patients. For image quality assessment, CTA images were evaluated on a three-point scale and signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated and compared. Furthermore, computed tomography (CT) dose index was recorded.

Results: Mean CT values and noise levels were higher in group A compared to group B (all P < .001), whereas SNR and CNR were lower than those in group B (all P < .001). Furthermore, the image quality of the aorta at the level of the diaphragm was lower in group A than that in group B (P < .05). However, image quality was graded as diagnostic in all patients, and motion artifacts of the aortic arch were significantly decreased in group A (P <.05). Interreader agreement was good or excellent for image quality assessment (k = 0.625-0.835). The 70-kVp CTA protocol, which allows dose reduction of 85%, was considered diagnostic in all instances by two readers.

Conclusions: Our proposed thoracic aortic CTA protocol provides diagnostic information with substantial reduction of both radiation and contrast agent doses compared to standard-pitch CTA at 100 kVp.

Keywords: Aorta; X-ray computed tomography; angiography; contrast agent; high pitch; radiation dose.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Aorta, Thoracic / diagnostic imaging*
  • Aortic Diseases / diagnostic imaging*
  • Aortography / methods*
  • Cardiac-Gated Imaging Techniques
  • Contrast Media / administration & dosage
  • Feasibility Studies
  • Female
  • Humans
  • Image Enhancement / methods
  • Image Interpretation, Computer-Assisted / methods*
  • Iohexol / administration & dosage
  • Iohexol / analogs & derivatives
  • Male
  • Middle Aged
  • Radiation Dosage*
  • Radiation Protection / methods
  • Reproducibility of Results
  • Sensitivity and Specificity
  • Tomography, X-Ray Computed / methods*

Substances

  • Contrast Media
  • Iohexol
  • iopromide