Mitochondria-targeted fluorescent thermometer monitors intracellular temperature gradient

Chem Commun (Camb). 2015 May 11;51(38):8044-7. doi: 10.1039/c5cc01088h. Epub 2015 Apr 13.

Abstract

Intracellular thermometry at the microscopic level is currently a hot topic. Herein we describe a small molecule fluorescent thermometer targeting mitochondria (Mito thermo yellow). Mito thermo yellow successfully demonstrates the ability to monitor the intracellular temperature gradient, generated by exogenous heating, in various cells.