Thoracic endovascular aortic repair after iatrogenic aortic dissection and false lumen stent grafting

Ann Thorac Surg. 2015 Apr;99(4):1447-9. doi: 10.1016/j.athoracsur.2014.05.101.

Abstract

Iatrogenic aortic dissections are a severe complication after thoracic endovascular aortic repair, and treatment guidelines do not exist. Herein, we report a patient who experienced an iatrogenic type B aortic dissection during elective thoracic endovascular aortic repair and suggest an interventional treatment option.

Publication types

  • Case Reports

MeSH terms

  • Aged
  • Angiography / methods
  • Aortic Aneurysm, Thoracic / diagnostic imaging
  • Aortic Aneurysm, Thoracic / surgery*
  • Aortic Dissection / diagnostic imaging
  • Aortic Dissection / etiology
  • Aortic Dissection / surgery*
  • Blood Vessel Prosthesis
  • Blood Vessel Prosthesis Implantation / adverse effects
  • Blood Vessel Prosthesis Implantation / methods*
  • Elective Surgical Procedures
  • Endovascular Procedures / adverse effects*
  • Endovascular Procedures / methods
  • Follow-Up Studies
  • Humans
  • Iatrogenic Disease*
  • Intraoperative Complications / diagnosis
  • Intraoperative Complications / surgery*
  • Male
  • Prosthesis Failure
  • Stents
  • Tomography, X-Ray Computed / methods
  • Treatment Outcome