Validity of activity monitors worn at multiple nontraditional locations under controlled and free-living conditions in young adult women

Appl Physiol Nutr Metab. 2015 May;40(5):448-56. doi: 10.1139/apnm-2014-0183. Epub 2015 Jan 12.

Abstract

The purpose of this study was to examine the validity of counting steps and computing indices of moderate-to-vigorous physical activity (MVPA) using miniature activity monitors with 3-D technology worn at various locations under controlled (CON) and free-living conditions (FL). Kenz e-style2, Tanita Calorism Smart, and Omron Calori Scan HJA-306 activity monitors were assessed. Nine and 31 young adult women were assigned to the CON and FL studies, respectively. While walking or jogging on a treadmill at 5 different speeds, the subjects simultaneously carried the 3 different monitors in a pants pocket (PP), a chest shirt pocket, and a shoulder bag (B). Under the FL condition, the 3 monitors were placed only at the PP and B locations for practical reasons. Significant effects of monitor location and walking/jogging speed on the step count measured by the 3 monitors were evaluated under the CON condition. Monitors placed at both PP and B tended to underestimate the number of steps; however, there were no significant differences between the values obtained with the Kenz monitor and those obtained with a criterion accelerometer under the FL condition. Moreover, strong correlations were observed between steps measured by monitors placed at PP and steps measured by the criterion accelerometer. The amount of MVPA for the PP location and the non-carrying duration of the bag for the B location were considered to be important determinants of the accuracy of step counting under the FL condition. In conclusion, monitors placed at the PP location, especially the Kenz monitor, showed acceptable accuracy for young adult women in real-life settings. In contrast, MVPA indices assessed using these monitors showed limited validity.

Keywords: Japanese; Japonais; accelerometer; accéléromètre; activité physique; exercise intensity; intensité d’exercice; locomotion; pedometer; physical activity; podomètre.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Accelerometry / instrumentation
  • Accelerometry / standards
  • Accelerometry / statistics & numerical data*
  • Activities of Daily Living
  • Adult
  • Clothing*
  • Exercise / physiology*
  • Exercise Test / statistics & numerical data*
  • Female
  • Humans
  • Monitoring, Ambulatory / instrumentation
  • Monitoring, Ambulatory / standards
  • Monitoring, Ambulatory / statistics & numerical data*
  • Physical Exertion / physiology
  • Reproducibility of Results
  • Running / physiology
  • Walking / physiology
  • Young Adult