[Evaluation of three methods for forensic diatom test]

Nan Fang Yi Ke Da Xue Xue Bao. 2015 Mar;35(3):427-31.
[Article in Chinese]

Abstract

Objective: To compare the efficacy of three methods for forensic diatom test, namely strong acid digestion-centrifuge enrichment-light microscopy (SD-CE-LM), microwave digestion-membrane filtration-automated scanning electron microscopy (MD-ME-SEM), and microwave digestion-membrane filtration-light microscopy (MD-MF-LM).

Methods: Sixty samples were randomly divided into 3 groups for diatom test using three methods, and the sample preparation time, degree of digestion and recovery rate of diatoms were compared.

Results: The sample preparation time was the shortest with MD-MF-LM and the longest with SD-CE-LM (P<0.05). MD-ME-SEM and MD-MF-LM allowed more thorough tissue digestion than SD-CE-LM. MD-ME-SEM resulted in the highest total recovery rate of diatom, followed by MD-MF-LM and then by SD-CE-LM (P<0.05); the recover rate of different diatom species was the highest with MD-ME-SEM, followed by MD-MF-LM and SD-CE-LM (P<0.05).

Conclusion: SD-CE-LM has a low recovery rate of diatoms especially for those with lengths shorter than 40 µm or densities less than 1/5. With a high recovery rate and accuracy in diatom test, MD-ME-SEM is suitable for diagnosis of suspected drowning cases. MD-MF-LM is highly efficient, sensitive and convenient for forensic diatom test.

Publication types

  • Comparative Study

MeSH terms

  • Centrifugation
  • Diatoms / isolation & purification*
  • Drowning*
  • Forensic Sciences / methods*
  • Humans
  • Microscopy
  • Microscopy, Electron, Scanning
  • Microwaves
  • Specimen Handling