Immediate loading with a novel implant featured by variable-threaded geometry, internal conical connection and platform shifting: three-year results from a prospective cohort study

Eur J Oral Implantol. 2015 Spring;8(1):51-63.

Abstract

Purpose: To evaluate the clinical and radiological performance of an immediately loaded novel implant design over a 3-year period.

Materials and methods: This prospective study includes 54 consecutive partially edentulous patients treated between December 2010 and October 2011. Outcome measures were: implant and prosthetic failures; biological and mechanical complications; marginal bone loss (MBL); sulcus bleeding index (SBI); and plaque score (PS).

Results: A total of 118 (29 narrow platform, 70 regular platform and 19 wide platform) NobelReplace Conical Connection implants were placed in both post-extraction sockets and healed sites and immediately loaded. The mean insertion torque was 63.4 ± 7.1 Ncm. One hundred out of 118 implants (84.7%) were inserted with a torque ranging between 55 and 70 Ncm. Each patient received a single prosthesis. At the 3-year follow-up, no patient dropped out and only two post-extractive implants failed (1.7%) in two patients (3.7%). The only complication (1.9%) observed was an event of periimplantitis, consisting of a mean mesiodistal peri-implant bone loss of 3.2 mm reported in a healed site of a smoker patient at the 2-year follow-up examination. No prosthesis failures were detected. The cumulative mean MBL between implant placements at the 3-year follow-up was 0.68 mm (95% CI: 0.44, 0.92). At the 3-year follow-up session, the SBI and PS were 5.7% and 15.4%, respectively.

Conclusions: The NobelReplace Conical Connection implant can be considered as a valuable treatment option for immediate implant placement and loading in the partially edentulous patients over a 3-year period. Insertion torques ranging between 55 and 70 Ncm are not detrimental to osseointegration.

MeSH terms

  • Adult
  • Aged
  • Aged, 80 and over
  • Alveolar Ridge Augmentation / methods
  • Bone Substitutes / therapeutic use
  • Cohort Studies
  • Dental Implant-Abutment Design*
  • Dental Implants*
  • Dental Plaque Index
  • Dental Prosthesis Design*
  • Dental Prosthesis, Implant-Supported
  • Dental Restoration Failure
  • Female
  • Follow-Up Studies
  • Humans
  • Immediate Dental Implant Loading*
  • Jaw, Edentulous, Partially / rehabilitation
  • Jaw, Edentulous, Partially / surgery
  • Male
  • Middle Aged
  • Minerals / therapeutic use
  • Peri-Implantitis / etiology
  • Periodontal Index
  • Prospective Studies
  • Tooth Socket / surgery
  • Torque
  • Treatment Outcome
  • Young Adult

Substances

  • Bio-Oss
  • Bone Substitutes
  • Dental Implants
  • Minerals