Radiation Exposure and Contrast Volume Differ between Transapical and Transfemoral Aortic Valve Implantation with the Edwards SAPIEN Aortic Valve

Thorac Cardiovasc Surg. 2015 Sep;63(6):479-86. doi: 10.1055/s-0034-1395983. Epub 2015 Feb 17.

Abstract

Background: To date, little is known about the radiation exposure and the amount of contrast medium given during the transcatheter aortic valve implantation (TAVI) procedure. This study compares our data between the transfemoral (TF) approach and the transapical (TA) approach.

Patients and methods: A total of 216 TA and 180 TF implantations of the Edwards SAPIEN (Edwards Lifesciences, Irvine, California, United States) valve were consecutively performed by our heart team, consisting of cardiac surgeons and cardiologists. Fluoroscopy time, dose area product, and contrast volume were compared between both the approaches.

Results: TF-TAVI showed higher values of fluoroscopy time (13.1 ± 5.9 vs. 7.0 ± 5.7 minutes, p < 0.001), dose area product (5.0 ± 3.9 vs. 2.7 ± 1.9 mGy·m(2), p < 0.001), and contrast volume (196.7 ± 72.7 vs. 109.2 ± 33.8 mL, p < 0.001). All physicians performing the TF approach exceeded the mean values of the surgeons performing the TA approach. Some physicians showed a trend toward lower values with growing experience. Vascular complications and postdilatation had only a minor impact on the study parameters.

Conclusion: TA-TAVI showed an advantage over TF-TAVI in terms of lower fluoroscopy time, dose area product, and contrast use. This was hardly reflected in the past and should be considered when comparing invasiveness of both methods. However, human factors also play a role as most physicians showed a learning curve toward lower values over time.

MeSH terms

  • Aged
  • Aged, 80 and over
  • Aortic Valve / surgery
  • Aortic Valve Stenosis / diagnostic imaging
  • Aortic Valve Stenosis / surgery*
  • Cardiac Catheterization / methods*
  • Contrast Media / administration & dosage*
  • Dose-Response Relationship, Drug
  • Dose-Response Relationship, Radiation
  • Female
  • Fluoroscopy / adverse effects*
  • Germany / epidemiology
  • Heart Valve Prosthesis Implantation / methods*
  • Humans
  • Incidence
  • Male
  • Radiation Exposure
  • Radiation Injuries / epidemiology*
  • Radiation Injuries / prevention & control
  • Retrospective Studies
  • Risk Assessment / methods*

Substances

  • Contrast Media