Preoperative ¹¹C-methionine PET/CT enables focused parathyroidectomy in MIBI-SPECT negative parathyroid adenoma

World J Surg. 2015 Jul;39(7):1750-7. doi: 10.1007/s00268-015-2992-x.

Abstract

Background: Precise preoperative localization is essential for focussed parathyroidectomy. The imaging standard consists of cervical ultrasonography (cUS) and (99m)Tc-MIBI-SPECT (MIBI-SPECT). (11)C-methionine positron emission tomography/computed tomography (Met-PET/CT) is a promising method for localizing parathyroid adenomas. The objective of our study was to elucidate whether additional Met-PET/CT increases the rate of focussed parathyroidectomy.

Methods: Fourteen patients with primary hyperparathyroidism (HPT) and three patients with tertiary HPT underwent cUS and MIBI-SPECT. Met-PET/CT was carried out in patients with negative MIBI results. Subsequent surgical strategy was adapted according to imaging results.

Results: cUS localized a single parathyroid adenoma in 10/17 patients (59 %), while MIBI-SPECT/CT identified 11/17 single adenomas (65 %). In the remaining six patients, Met-PET/CT identified five single adenomas. This step-up approach correctly identified single adenomas in 16/17 patients (94 %).

Conclusion: Met-PET/CT raises the rate of correctly localized single parathyroid adenomas in patients with negative cUS and MIBI-SPECT/CT and increases the number of focussed surgical approaches.

MeSH terms

  • Adenoma / diagnostic imaging*
  • Adenoma / surgery*
  • Aged
  • Carbon Radioisotopes
  • Female
  • Humans
  • Hyperparathyroidism, Primary / diagnostic imaging
  • Hyperparathyroidism, Primary / etiology
  • Male
  • Methionine
  • Middle Aged
  • Parathyroid Neoplasms / diagnostic imaging*
  • Parathyroid Neoplasms / surgery*
  • Parathyroidectomy*
  • Preoperative Period
  • Sensitivity and Specificity
  • Technetium Tc 99m Sestamibi
  • Tomography, Emission-Computed, Single-Photon / methods*
  • Ultrasonography

Substances

  • Carbon Radioisotopes
  • Technetium Tc 99m Sestamibi
  • Methionine