One-year outcomes in unselected patients treated with a thin-strut, platinum-chromium, paclitaxel-eluting stent: primary endpoint results from the TAXUS Element European post-approval surveillance study (TE-PROVE)

EuroIntervention. 2015 Mar;10(11):1261-6. doi: 10.4244/EIJY15M01_01.

Abstract

Aims: To evaluate clinical outcomes in patients receiving the next-generation, paclitaxel-eluting, platinum-chromium TAXUS Element stent in a real-world setting. The PERSEUS Workhorse and Small Vessel studies showed positive results with the TAXUS Element stent in a clinical trial setting.

Methods and results: TE-PROVE was a prospective, open-label, multicentre, "all-comers" study which enrolled 1,014 patients at 37 European sites. Follow-up was at 30 days, six months and one year, and will continue annually up to five years. The primary endpoint was overall and stent-related target vessel failure (TVF), defined as cardiac death, target vessel-related myocardial infarction (MI) and target vessel revascularisation (TVR) at one year post implantation. Secondary endpoints included the components of TVF, all-cause mortality, and ARC definite/probable stent thrombosis. Follow-up was available in 97.3% (987/1,014) of patients. Patients were 75.0% male (760/1,014), mean age was 65.1±10.8 years, 25.5% had medically treated diabetes (259/1,014), and 10.7% (109/1,014) were treated for STEMI. At baseline, mean lesion length among 1,299 treated lesions was 19.8±12.0 mm and mean reference vessel diameter was 3.1±0.5 mm. At one year, the rate of TVF (primary endpoint) was 6.0% (59/987) overall; 3.7% (37/987) of TVF events were stent-related. Cardiac death was 0.7% (7/987), target vessel-related MI was 1.1% (11/987), and TVR was 4.7% (46/987). All-cause death occurred in 1.2% (12/987) of patients and ARC definite/probable ST was 0.5% (5/987).

Conclusions: The primary endpoint results from the TE-PROVE registry demonstrate good performance and safety for the TAXUS Element paclitaxel-eluting stent at one year in everyday clinical practice.

Clinical trial registration information: NCT01242696.

Publication types

  • Multicenter Study
  • Observational Study
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Aged
  • Cardiovascular Diseases / mortality
  • Chromium*
  • Coronary Restenosis / epidemiology
  • Coronary Stenosis / drug therapy
  • Coronary Stenosis / surgery*
  • Drug-Eluting Stents*
  • Europe
  • Female
  • Humans
  • Male
  • Middle Aged
  • Myocardial Infarction / drug therapy
  • Myocardial Infarction / epidemiology
  • Myocardial Infarction / surgery*
  • Myocardial Revascularization / statistics & numerical data
  • Paclitaxel / therapeutic use*
  • Percutaneous Coronary Intervention / instrumentation
  • Platinum*
  • Product Surveillance, Postmarketing
  • Prospective Studies
  • Reoperation
  • Treatment Failure
  • Treatment Outcome
  • Tubulin Modulators / therapeutic use*

Substances

  • Tubulin Modulators
  • Chromium
  • Platinum
  • Paclitaxel

Associated data

  • ClinicalTrials.gov/NCT01242696