Prognostic relevance of cardiac troponin T levels and their dynamic changes measured with a high-sensitivity assay in acute ischaemic stroke: analyses from the TRELAS cohort

Int J Cardiol. 2014 Dec 20;177(3):886-93. doi: 10.1016/j.ijcard.2014.10.036. Epub 2014 Oct 22.

Abstract

Background/objectives: To assess the prognostic relevance of cardiac troponin T (cTnT) values and their serial changes as measured with a high-sensitivity assay in acute ischaemic stroke.

Methods and results: In total, 1016 consecutive acute ischaemic stroke patients were registered prospectively within a two-year period. High-sensitivity cTnT was quantitated on admission and the following day. Patients were stratified into three groups: below the 99 th percentile of a healthy reference population (< 14 ng/l; n = 409), moderately elevated cTnT (below the median of remaining patients, 14-30 ng/l; n=299) and high cTnT (> 30 ng/l; n = 308). Outcome measures were unfavourable outcome (modified Rankin Scale ≥ 2 at hospital discharge, n=604) and in-hospital mortality (n = 36). Peak cTnT levels were significantly associated with unfavourable outcome (adjusted odds ratios versus reference for moderately elevated cTnT 1.7, 95% confidence interval [CI] 1.1-2.7 and for high cTnT 3.1, 95% CI 1.8-5.6). The optimal cut-off for determining unfavourable outcome proved to be 16 ng/l. Adding this cut-off to clinical variables led to a significant improvement of c-statistics (0.851 versus 0.838, p=0.02). Dynamic changes (δ ≥ 50%) of cTnT were detected in 137 patients (13%). Multiple Cox regression analysis showed an independent association of dynamic changes in cTnT with in-hospital mortality (hazard ratio 2.3, 95% CI 1.1-4.7). The model-fitting (p<0.001) and c-statistics (0.889 versus 0.863, p = 0.08) improved most after dynamic change in cTnT had been added to a regression model which included clinical variables alone.

Conclusions: Our study adds novel findings relevant for interpretation of highly sensitive cTnT assays in acute ischaemic stroke: a) Myocardial injury is detectable in more than half of patients; b) even moderately elevated cTnT is associated with unfavourable outcome (optimal cut-off 16 ng/l); and c) dynamic changes in cTnT indicate an increased risk of in-hospital death.

Keywords: Dynamics; High-sensitivity assay; Ischaemic stroke; Mortality; Outcome; Troponin.

MeSH terms

  • Aged
  • Aged, 80 and over
  • Biomarkers / blood
  • Brain Ischemia / blood*
  • Brain Ischemia / diagnosis*
  • Brain Ischemia / mortality
  • Cohort Studies
  • Female
  • Hospital Mortality / trends
  • Humans
  • Male
  • Middle Aged
  • Prognosis
  • Prospective Studies
  • Registries
  • Stroke / blood*
  • Stroke / diagnosis*
  • Stroke / mortality
  • Troponin T / blood*

Substances

  • Biomarkers
  • Troponin T