Effective identification of functional hearing loss using behavioral threshold measures

J Speech Lang Hear Res. 2015 Apr;58(2):453-65. doi: 10.1044/2014_JSLHR-H-14-0066.

Abstract

Purpose: Four functional hearing loss protocols were evaluated.

Method: For each protocol, 30 participants feigned a hearing loss first on an audiogram and then for a screening test that began a threshold search from extreme levels (-10 or 90 dB HL). Two-tone and 3-tone protocols compared thresholds for ascending and descending tones for 2 (0.5 and 1.0 kHz) and 3 (0.5, 1.0, and 2.0 kHz) frequencies, respectively. A noise-band protocol compared an ascending noise-band threshold with that for 2 descending tones (0.5 and 1.0 kHz). A spondee protocol compared an ascending spondee threshold with that for 2 descending tones (0.5 and 1.0 kHz). These measures were repeated without the participants feigning losses.

Results: With nonfeigning participants, ascending and descending threshold differences were minimal for all protocols. When the participants feigned a loss, the spondee protocol produced the largest average threshold difference (30.8 dB), whereas the other protocols produced smaller differences (19.6-22.2 dB).

Conclusions: Using both the screening test and a comparison of the initial audiogram with the screening test, the spondee and 3-tone protocols resulted in 100% true positives and 0% false positives for functional hearing loss. Either of these protocols could be used clinically or in occupational hearing conservation programs.

Publication types

  • Evaluation Study
  • Research Support, U.S. Gov't, Non-P.H.S.

MeSH terms

  • Acoustic Stimulation / methods
  • Adult
  • Audiometry, Pure-Tone / methods
  • Auditory Threshold
  • Female
  • Hearing Loss, Functional / diagnosis*
  • Hearing Tests / methods*
  • Humans
  • Male
  • Noise
  • Psychoacoustics