Application of 3-dimensional printing technology to construct an eye model for fundus viewing study

PLoS One. 2014 Nov 13;9(11):e109373. doi: 10.1371/journal.pone.0109373. eCollection 2014.

Abstract

Objective: To construct a life-sized eye model using the three-dimensional (3D) printing technology for fundus viewing study of the viewing system.

Methods: We devised our schematic model eye based on Navarro's eye and redesigned some parameters because of the change of the corneal material and the implantation of intraocular lenses (IOLs). Optical performance of our schematic model eye was compared with Navarro's schematic eye and other two reported physical model eyes using the ZEMAX optical design software. With computer aided design (CAD) software, we designed the 3D digital model of the main structure of the physical model eye, which was used for three-dimensional (3D) printing. Together with the main printed structure, polymethyl methacrylate(PMMA) aspherical cornea, variable iris, and IOLs were assembled to a physical eye model. Angle scale bars were glued from posterior to periphery of the retina. Then we fabricated other three physical models with different states of ammetropia. Optical parameters of these physical eye models were measured to verify the 3D printing accuracy.

Results: In on-axis calculations, our schematic model eye possessed similar size of spot diagram compared with Navarro's and Bakaraju's model eye, much smaller than Arianpour's model eye. Moreover, the spherical aberration of our schematic eye was much less than other three model eyes. While in off- axis simulation, it possessed a bit higher coma and similar astigmatism, field curvature and distortion. The MTF curves showed that all the model eyes diminished in resolution with increasing field of view, and the diminished tendency of resolution of our physical eye model was similar to the Navarro's eye. The measured parameters of our eye models with different status of ametropia were in line with the theoretical value.

Conclusions: The schematic eye model we designed can well simulate the optical performance of the human eye, and the fabricated physical one can be used as a tool in fundus range viewing research.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Astigmatism / physiopathology
  • Computer Simulation
  • Cornea / anatomy & histology*
  • Corneal Topography / methods*
  • Fundus Oculi*
  • Humans
  • Lenses, Intraocular
  • Models, Anatomic*
  • Polymethyl Methacrylate
  • Printing, Three-Dimensional*
  • Refractive Errors / physiopathology

Substances

  • Polymethyl Methacrylate

Grants and funding

Funding from the National Basic Research Program of China (973 Program): No. 2011CB510200 (http://www.973.gov.cn/English/Index.aspx) to Qinghuai Liu; National Basic Research Program of China (973 Program): No. 2013CB967500 (http://www.973.gov.cn/English/Index.aspx) to Qinghuai Liu; National Natural Science Foundation of China: No. 81170855 (http://www.nsfc.gov.cn) to Qinghuai Liu; National Natural Science Foundation of China: No. 60977008 (http://www.nsfc.gov.cn) to Zhishan Gao. The funders had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscript.