Deformable registration of preoperative MR, pre-resection ultrasound, and post-resection ultrasound images of neurosurgery

Int J Comput Assist Radiol Surg. 2015 Jul;10(7):1017-28. doi: 10.1007/s11548-014-1099-4. Epub 2014 Nov 6.

Abstract

Purpose: Sites that use ultrasound (US) in image-guided neurosurgery (IGNS) of brain tumors generally have three sets of imaging data: preoperative magnetic resonance (MR) image, pre-resection US, and post-resection US. The MR image is usually acquired days before the surgery, the pre-resection US is obtained after the craniotomy but before the resection, and finally, the post-resection US scan is performed after the resection of the tumor. The craniotomy and tumor resection both cause brain deformation, which significantly reduces the accuracy of the MR-US alignment.

Method: Three unknown transformations exist between the three sets of imaging data: MR to pre-resection US, pre- to post-resection US, and MR to post-resection US. We use two algorithms that we have recently developed to perform the first two registrations (i.e., MR to pre-resection US and pre- to post-resection US). Regarding the third registration (MR to post-resection US), we evaluate three strategies. The first method performs a registration between the MR and pre-resection US, and another registration between the pre- and post-resection US. It then composes the two transformations to register MR and post-resection US; we call this method compositional registration. The second method ignores the pre-resection US and directly registers the MR and post-resection US; we refer to this method as direct registration. The third method is a combination of the first and second: it uses the solution of the compositional registration as an initial solution for the direct registration method. We call this method group-wise registration.

Results: We use data from 13 patients provided in the MNI BITE database for all of our analysis. Registration of MR and pre-resection US reduces the average of the mean target registration error (mTRE) from 4.1 to 2.4 mm. Registration of pre- and post-resection US reduces the average mTRE from 3.7 to 1.5 mm. Regarding the registration of MR and post-resection US, all three strategies reduce the mTRE. The initial average mTRE is 5.9 mm, which reduces to 3.3 mm with the compositional method, 2.9 mm with the direct technique, and 2.8 mm with the group-wise method.

Conclusion: Deformable registration of MR and pre- and post-resection US images significantly improves their alignment. Among the three methods proposed for registering the MR to post-resection US, the group-wise method gives the lowest TRE values. Since the running time of all registration algorithms is less than 2 min on one core of a CPU, they can be integrated into IGNS systems for interactive use during surgery.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Algorithms
  • Brain / pathology
  • Brain / surgery*
  • Brain Neoplasms / diagnostic imaging
  • Brain Neoplasms / pathology
  • Brain Neoplasms / surgery*
  • Craniotomy
  • Echoencephalography*
  • Humans
  • Imaging, Three-Dimensional / methods*
  • Magnetic Resonance Imaging
  • Neurosurgical Procedures / methods*
  • Preoperative Care