CFD simulation of vertical linear motion mixing in anaerobic digester tanks

Water Environ Res. 2014 Sep;86(9):816-27. doi: 10.2175/106143014x14062131177836.

Abstract

Computational fluid dynamics (CFD) was used to simulate the mixing characteristics of a small circular anaerobic digester tank (diameter 6 m) equipped sequentially with 13 different plunger type vertical linear motion mixers and two different type internal draft-tube mixers. Rates of mixing of step injection of tracers were calculated from which active volume (AV) and hydraulic retention time (HRT) could be calculated. Washout characteristics were compared to analytic formulae to estimate any presence of partial mixing, dead volume, short-circuiting, or piston flow. Active volumes were also estimated based on tank regions that exceeded minimum velocity criteria. The mixers were ranked based on an ad hoc criteria related to the ratio of AV to unit power (UP) or AV/UP. The best plunger mixers were found to behave about the same as the conventional draft-tube mixers of similar UP.

MeSH terms

  • Anaerobiosis
  • Bioreactors*
  • Computer Simulation*
  • Hydrodynamics*
  • Models, Theoretical*