Impact of urinary stone volume on computed tomography stone attenuations measured in Hounsfield units in a large group of Austrian patients with urolithiasis

Cent European J Urol. 2014;67(3):289-95. doi: 10.5173/ceju.2014.03.art16. Epub 2014 Aug 18.

Abstract

Introduction: To investigate retrospectively the impact of urinary stone volume on computed tomography stone attenuations measured in Hounsfield units in 253 patients with urolithiasis.

Material and methods: CT scans were performed in 253 patients with suspected urinary stone disease from 2008 to 2010 using CT-Scanner Siemens, SOMATOM, Sensation 64. One experienced radiologist (A.L) who was blinded to the chemical composition of the stones retrospectively reviewed images and analyzed data to determine the composition of the stones. The results were compared with the biochemical analysis results obtained by infrared spectroscopy (100 FTIR, PerkinElmer).

Results: 253 consecutive patients from 2008 to 2010 were included into analysis: 189 males, and 64 females. Mean age was 51.2. According to stone volume, stones were divided into 2 groups: 126 stones with volume of 4.3 mm or more, 127 stones with volume less than 4.3 mm. There was a significant relationship between stone volume and its CT attenuation only in stones with a volume 4.3 mm or more (p <0.05).

Conclusions: We failed to show a significant relationship between stone volume and its attenuations in Hounsfield units. We could not distinguish uric acid stones from non uric acid stones.

Keywords: Hounsfield units; computed tomography; none uric acid stones; regions of interest; shock wave lithotripsy; uric acid stones.