Localization and Retrieval of an Eyelid Metallic Foreign Body With an Oscillating Magnet and High-Resolution Ultrasonography

Ophthalmic Plast Reconstr Surg. 2016 Jul-Aug;32(4):e83-4. doi: 10.1097/IOP.0000000000000257.

Abstract

A patient was found to have a metallic foreign body in the left anterior orbit on CT imaging, but the foreign body was not evident on clinical examination. On high-resolution ultrasonography, an object was identified in the left upper eyelid; however, the typical shadow with metallic foreign bodies was not seen. A high-power oscillating magnet was then applied to the eyelid, which revealed a subcutaneous metallic foreign body in the left upper eyelid. When used in conjunction, the high-resolution ultrasound and oscillating magnet successfully localized and facilitated retrieval of the metallic foreign body from the left upper eyelid.

Publication types

  • Case Reports

MeSH terms

  • Eye Foreign Bodies / diagnosis*
  • Eye Foreign Bodies / therapy
  • Eyelids / diagnostic imaging
  • Eyelids / injuries*
  • Humans
  • Image Processing, Computer-Assisted*
  • Magnetic Resonance Imaging
  • Magnets*
  • Male
  • Middle Aged
  • Surgery, Computer-Assisted / methods*
  • Ultrasonography / methods*