Functional outcome following a large head total hip arthroplasty: A retrospective analysis of mid term results

Indian J Orthop. 2014 Jul;48(4):410-4. doi: 10.4103/0019-5413.136295.

Abstract

Background: One of the reasons that hip resurfacing and large head metal on metal (MOM) total hip arthroplasty (THA) became popular in Asia was the possible increased range of movement and thereby improved function of the hip joint. Due to concerns of MOM articulation an alternative bearing was sought. Hence, a shift from large head MOM to large head ceramic on ceramic (COC) was made. The aim of this study was to compare the functional outcome including range of motion (ROM) and dislocation rates following large head MOM and large head COC THA.

Materials and methods: Retrospectively, 39 primary THA with large head MOM with a mean age of 56 years (range 36-72 years) and average followup of 54 months (range 38-70 months) were compared with 23 primary THA with large head COC bearing with a mean age of 48 years (range 36-68 years) and an average followup of 18 months (range 12-26 months). Functional outcome was assessed using the Modified Harris Hip Score. Dislocation rate and ROM were compared.

Results: Global ROM averaged 248 degrees with MOM group and 252 degrees with the COC group. One patient with metal bearing had dislocation at an average 3 year followup which required revision THA while there were no complications in the COC group. MHHS averaged 89 points in MOM and 94 in COC THR.

Conclusion: This study has shown that large head ceramic on ceramic THA is a good alternative to large head metal on metal THA with comparable dislocation rates and range of movements and without complications of metallosis in Asian patients.

Keywords: Arthroplasty; Ceramic bearing; hip; large head; metal bearing; prosthesis design; replacement; total hip arthroplasty.