Intra-colonic administration of a polymer-bound NIRF probe for improved colorectal cancer detection during colonoscopy

J Control Release. 2014 Oct 28:192:182-91. doi: 10.1016/j.jconrel.2014.06.058. Epub 2014 Jul 6.

Abstract

There is increasing interest in the use of nanoparticle imaging probes for cancer diagnosis. However, various biological barriers limit the efficient delivery of nanoparticles to tumors following parenteral administration. We have investigated the applicability of a water-soluble polymeric imaging probe for improving the detection of gastrointestinal (GI) tumors after intra-luminal (colonic) administration. N-(2-hydroxypropyl)methacrylamide (HPMA) copolymers bearing either fluorescein-isothiocyanate (FITC) or near-infrared fluorescence (NIRF) dye (IR-783) were conjugated with EPPT1 peptide, derived from the CDR3 Vh region of a monoclonal antibody (ASM2) raised against human epithelial cancer cells, for targeting under-glycosylated mucin-1 (uMUC-1) expressed in neoplastic tissues. The targeted FITC-labeled copolymer, P-(EPPT1)-FITC, was investigated for its ability to bind human CRC cells and tissue specimens in vitro. The uMUC-1-targeted NIRF-labeled copolymer, P-(EPPT1)-IR783, was assessed for its ability to detect colonic lesions in vivo. P-(EPPT1)-FITC demonstrated superior binding to colorectal cancer (CRC) cells that over-express the uMUC-1 antigen and exhibited selectivity towards human CRC tissue specimens, as compared to adjacent normal tissues from the same patient. When applied intra-colonically, P-(EPPT1)-IR783 significantly accumulated in cancerous tissue, relative to the adjacent normal mucosa of HT29 and LS174T tumor-bearing mice, and demonstrated higher signal intensities in colonic tumors, as compared to the non-targeted P-(GG-OH)-IR783 probe (i.e., without EPPT1). We found that P-(GG-OH)-IR783 can also accumulate specifically at tumor sites. The cancer-specific uptake and retention of P-(GG-OH)-IR783 was not mediated by organic anion transporting peptides (OATPs). Our findings indicate that the polymer-bound NIRF probe can successfully detect solid tumors in the GI tract following intra-colonic administration, and could be used in conjunction with colonoscopic procedures to improve the sensitivity of colonoscopies for polyp detection.

Keywords: Colorectal cancer; HPMA copolymer; Imaging probe; Intracolonic administration; Near infrared fluorescence.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Acrylamides* / administration & dosage
  • Acrylamides* / chemistry
  • Amino Acid Sequence
  • Animals
  • Cell Line, Tumor
  • Colon / metabolism
  • Colon / pathology*
  • Colonoscopy / methods*
  • Colorectal Neoplasms / diagnosis*
  • Colorectal Neoplasms / metabolism
  • Colorectal Neoplasms / pathology
  • Drug Delivery Systems
  • Female
  • Fluorescent Dyes* / administration & dosage
  • Fluorescent Dyes* / chemistry
  • Humans
  • Mice
  • Mice, Nude
  • Molecular Sequence Data
  • Mucin-1 / metabolism*
  • Optical Imaging
  • Peptides* / administration & dosage
  • Peptides* / chemistry
  • Peptides* / metabolism
  • Rectum / metabolism
  • Rectum / pathology

Substances

  • Acrylamides
  • Fluorescent Dyes
  • Mucin-1
  • Peptides
  • N-(2-hydroxypropyl)methacrylamide