Analytic solution for N-electrode actuated piezoelectric disk with application to piezoelectric micromachined ultrasonic transducers

IEEE Trans Ultrason Ferroelectr Freq Control. 2013 Aug;60(8):1756-67. doi: 10.1109/TUFFC.2013.2756.

Abstract

In this work, the deflection equation of a piezoelectrically-driven micromachined ultrasonic transducer (PMUT) is analytically determined using a Green's function approach. With the Green's function solution technique, the deflection of a circular plate with an arbitrary circular/ring electrode geometry is explicitly solved for axisymmetric vibration modes. For a PMUT with one center electrode covering ≈60% of the plate radius, the Green's function solution compares well with existing piece-wise and energy-based solutions with errors of less than 1%. The Green's function solution is also simpler than them requiring no numerical integration, and applies to any number of axisymmetric electrode geometries. Experimentally measured static deflection data collected from a fabricated piezoelectric micro ultrasonic transducer (PMUT) is further used to validate the Green's function model analysis. The center deflection and deflection profile data agree well with the Green's function solution over a range of applied bias voltages (5 to 21 V) with the average error between the experimental and Green's function data less than 9%.

Publication types

  • Research Support, Non-U.S. Gov't
  • Research Support, U.S. Gov't, Non-P.H.S.