Establishment of a bilateral femoral large segmental bone defect mouse model potentially applicable to basic research in bone tissue engineering

J Surg Res. 2014 Dec;192(2):454-63. doi: 10.1016/j.jss.2014.05.037. Epub 2014 May 27.

Abstract

Background: To understand the cellular mechanism underlying bone defect healing in the context of tissue engineering, a reliable, reproducible, and standardized load-bearing large segmental bone defect model in small animals is indispensable. The aim of this study was to establish and evaluate a bilateral femoral defect model in mice.

Materials and methods: Donor mouse bone marrow mesenchymal stem cells (mBMSCs) were obtained from six mice (FVB/N) and incorporated into partially demineralized bone matrix scaffolds to construct tissue-engineered bones. In total, 36 GFP(+) mice were used for modeling. Titanium fixation plates with locking steel wires were attached to the femurs for stabilization, and 2-mm-long segmental bone defects were created in the bilateral femoral midshafts. The defects in the left and right femurs were transplanted with tissue-engineered bones and control scaffolds, respectively. The healing process was monitored by x-ray radiography, microcomputed tomography, and histology. The capacity of the transplanted mBMSCs to recruit host CD31(+) cells was investigated by immunofluorescence and real-time polymerase chain reaction.

Results: Postoperatively, no complication was observed, except that two mice died of unknown causes. Stable fixation of femurs and implants with full load bearing was achieved in all animals. The process of bone defect repair was significantly accelerated due to the introduction of mBMSCs. Moreover, the transplanted mBMSCs attracted more host CD31(+) endothelial progenitors into the grafts.

Conclusions: The present study established a feasible, reproducible, and clinically relevant bilateral femoral large segmental bone defect mouse model. This model is potentially suitable for basic research in the field of bone tissue engineering.

Keywords: Bilateral bone defect; Mesenchymal stem cells; Mouse model; Tissue engineering.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Animals
  • Bone Plates
  • Bone Transplantation / methods
  • Disease Models, Animal*
  • Femoral Fractures* / diagnostic imaging
  • Femoral Fractures* / surgery
  • Femoral Fractures* / therapy
  • Femur / diagnostic imaging
  • Femur / injuries
  • Femur / surgery
  • Fracture Healing
  • Green Fluorescent Proteins / genetics
  • Male
  • Mesenchymal Stem Cell Transplantation / methods*
  • Mesenchymal Stem Cells / cytology*
  • Mice, Inbred Strains
  • Mice, Transgenic*
  • Osteogenesis
  • Prostheses and Implants
  • Radiography
  • Reproducibility of Results
  • Tissue Engineering / methods*
  • Weight-Bearing

Substances

  • Green Fluorescent Proteins